Clocks, Clock ratio – FUJITSU MB91460 SERIES FR60 User Manual

Page 982

Advertising
background image

966

Chapter 50 Subclock Calibration Unit

4.Clocks

4. Clocks

The module operates with 3 different clocks: The 4 MHz clock OSC4, the 32 kHz clock OSC32 (ot the 100kHz
clock OSC100) and the peripheral clock CLKP. Synchronization circuits adapt the different domains.

The clock frequencies have to fulfill the following requirements:

Clock ratio

T

OSC32/OSC100

> 2 x T

OSC4

+ 3 x T

CLKP

T

OSC4

< 1/2 x T

OSC32/OSC100

- 3/2 x T

CLKP

T

CLKP

< 1/3 x T

OSC32/OSC100

- 2/3 x T

OSC4

The input frequencies must not exceed the values given in Table

4-1

.

Table 4-1 Maximum operation frequencies

Table 4-2 Example of valid clock ratios which fulfill requirements 1 and 2

OSC32/OSC100

OSC4

CLKP

maximum

2 MHz

500 ns

10 MHz

100 ns

50 MHz

20 ns

OSC32

OSC100

OSC4

CLKP

maximum operation

speed

2 MHz

500 ns

2 MHz

500 ns

10 MHz

100 ns

50 MHz

20 ns

normal operation

32 kHz

31.25 us

100 kHz

10 us

4 MHz

250 ns

>2 MHz

500 ns

Advertising