FUJITSU MB91460 SERIES FR60 User Manual
Page 767
Advertising

751
Chapter 36 Input Capture
4.Register
• bit3-bit2: Input capture 1 active edge selection
• Select the active capture edge for the input capture signal from external pin (ICU1)
• If the active edge selection bit is “00”, input capture 1 is stopped.
• bit1-bit0: Input capture 0 active edge selection
• Select the active capture edge for the input capture signal for external pin (ICU0).
• When the active edge selection bit is “00”, input capture 0 is stopped.
EG11
EG10
Edge selection
0
0
Stop input capture
0
1
Rising edge
1
0
Falling edge
1
1
Both edges (rising edge and falling edge)
EG01
EG00
Edge selection
0
0
Stop input capture
0
1
Rising edge
1
0
Falling edge
1
1
Both edges (rising edge and falling edge)
Advertising