4. Slide the upper sensor along the slot to the desired position. When using

label stock that has a gap between labels (die-cut labelstock), position
the media sensor anywhere along the gap EXCEPT where the rounded
corners of the label are detected. When using tagstock, position the
upper sensor directly over the hole or notch.

5. Tighten the screw.

Lower Media Sensor Adjustment

Refer to Figure 5 throughout this procedure.

1. Locate the Lower Media Sensor assembly (a spring clip holding a circuit

board) near the bottom rear of the printhead assembly.

2. Position the sensor by sliding it in its slot so that the two brass-colored

infrared emitters are centered under the upper sensor.

3. If you are moving the sensor away from the printer’s main frame:

Gently pull wires out of the printer frame as required. (Wires should
have a little slack.) Call a service technician if there is not enough slack

Figure 5. Lower Media Sensor Adjustment