Routine Care and Adjustment

62

Zebra XiII Printer User’s Guide

Printhead Pressure Adjustment

This adjustment may be necessary if printing is too light on one side or if
thick media is used. Refer to Figure 14.

1. Perform the Toggle Positioning procedure above. If the problem is

solved, you may stop here; otherwise, continue with the rest of this pro-
cedure.

2. Print some labels at Speed A, such as by running the Pause test (see

page 71).

3. While printing labels, lower the Darkness setting until a gray level of

printing is seen.

4. Loosen the knurled (upper) locking nuts at the top of the toggle assem-

bly/assemblies.

5. Increase or decrease spring pressure (using the knurled adjustment nuts

on the shafts of the toggles) until the left and right edges of printed area
are equally dark.

Note:

Printhead life can be maximized by using the lowest pressure that produces
the desired print quality.

6. Increase Darkness to optimum level for the media being used.

7. Retighten locking nuts.

Media Sensor Position Adjustment

See “Adjusting the Transmissive Media Sensor Assembly Position” on
page 15.