Troubleshooting and Diagnostics

68

Zebra XiII Printer User’s Guide

A label format was sent to
the printer but not recog-
nized. Data light flashes but
no printing occurs.

Communications parameters are
incorrect.

Print a Communications Diagnostic
label. Check for Format or Overrun
Errors. Reset Communication
Parameters (see page 42).

Prefix and delimiter characters set
in printer do not match the ones
used in the label format.

Set the characters in the printer to
match the label format. See “Select-
ing Prefix and Delimiter Characters”
on page 42.

If the problem continues, check the
ZPL II format for changed ^CC,
^CT, and ^CD commands.

A batch of labels was sent.
Several labels print then
printer skips, misplaces,
misses, or distorts the print-
ing on the labels.

Buffer is overfilling.

Check for proper flow control set-
ting. Refer to “Configuration and
Calibration” in Chapter 2.

Table 6. Troubleshooting (Continued)