Changing password-protected parameters, Leaving the program mode – Genicom microLaser 170 User Manual

Page 45

Advertising
background image

Operation

32

Zebra XiII Printer User’s Guide

An asterisk (*) in the upper left hand corner of the display indicates that the
value displayed is different than the currently stored value.

Changing Password-Protected Parameters

Certain parameters are password-protected by factory default.

CAUTION:

Do not change password-protected parameters unless you’re sure you know
what you’re doing! If they are set incorrectly, these parameters could cause
the printer to function in an unpredictable way.

The first attempt to change one of these parameters (pressing one of the
black oval keys) will require you to enter a four-digit password. This is
done via the

“ENTER PASSWORD”

display. The left black oval key changes

the selected digit position. The right black oval key increases the selected
digit value. After entering the password, press the Next/Save key. The
parameter you are trying to change will be displayed. If the password was
entered correctly, you can now change the value.

The default password value is 1234. The password can be changed using the
^KP (Define Password) ZPL II

instruction.

Note:

Once the password has been entered correctly, it will not have to be entered
again unless you leave and re-enter the programming mode using the Setup/
Exit key.

Note:

You can disable the password protection feature so that it no longer prompts
you for a password by setting the password to ШШШШ via the ^KPØ ZPL/
ZPL II

command. To re-enable the password-protection feature, send the

ZPL/ZPL II

command ^KPx, where “x” can be any number, 1-4 digits in

length, except Ø.

Leaving the Program Mode

You can leave the Program Mode at any time by pressing the Setup/Exit
key. The

SAVE CHANGES

display will appear. There are five choices,

xi2ch2 Page 32 Tuesday, April 23, 1996 1:45 PM

Advertising
This manual is related to the following products: