B–3

B.5

Packet Structure

Controller-to-target:

Start of Packet

Target Address

Address

De-limiter

Instruction

Code

Code

Qualifier

Optional

Arguments

End of Packet

<

ASCII code 60

(1 character)



(4 characters)

/

ASCII code 47

(1 character)



(3 characters)

= or ?

ASCII code 61

or 63

(1 character)



(n characters)

Carriage Return

ASCII code 13

(1 character)


Example: <0135/TFQ=70.2345{CR}

Target-to-controller:

Start of Packet

Target

Address

Address

De-limiter

Instruction

Code

Code Qualifier

Optional

Arguments

End of Packet

>

ASCII

code 62

(1 character)



(4 characters)

/

ASCII

code 47

(1 character)



(3 characters)

=, ?, !, or *

ASCII code 61,

63, 33 or 42

(1 character)


(From 0 to n

characters)

Carriage Return,

Line Feed

ASCII code 13,10

(2 characters)


Example: >0654/RSW=32{CR}{LF}

Each of the components of the packet is now explained.

B.5.1

Start Of Packet

Controller to Target: This is the character ‘<’ (ASCII code 60)

Target to Controller: This is the character ‘>’ (ASCII code 62)
Because this is used to provide a reliable indication of the start of packet, these two
characters may not appear anywhere else within the body of the message.

B.5.2 Address

Up to 9999 devices can be uniquely addressed. In EIA-232 applications this value is set
to 0. In EIA-485 applications, the permissible range of values is 1 to 9999. It is
programmed into a target unit using the front panel keypad.