Mocomtech SLM-5650 User Manual

Page 142

Advertising
background image

SLM-5650 Satellite Modem

Revision 1

Remote Control

MN/SLM5650.IOM

B–20

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

IP Address

IPA=

18 bytes,
numerical

Command or Query.
Used to set the IP address and network prefix for the
10/100 BaseTx Ethernet management port, in the format:
xxx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (0-31)
Example: 010.006.030.001.24

IPA=
IPA?
IPA*
IPA#

IPA? IPA=

xx.xxx.xxx.xxx.yy

(see description of
arguments)

Carrier Only
Test Modes

COM=

1 byte, value
of 0 thru 2

Command or Query.
Test Mode, where:
0= Normal Mode (no test)
1=Tx CW
2=Tx Alternating 1,0 Pattern

Example: COM=1 (CW Mode)

COM=
COM?
COM*
COM#

COM? COM=x

(see description of
arguments)

Loopback
Test Modes

LOP=

1 byte, value
of 0 thru 3

Command or Query.
Loopback Test Modes, where:
0=Normal Mode (no test)
1=IF Loopback
2=I/O Loopback #1
3=I/O Loopback #2

Example: LOP=1 (IF Loopback)

LOP=
LOP?
LOP*
LOP#

LOP? LOP=x

(see description of
arguments)

Tx BERT
State

BTX=

1 byte, value
of 0 or 1

Command or Query.
Tx BERT State, where:
0=Off
1=On

Example: BTX=1 (Tx BERT On)

BTX=
BTX?
BTX*
BTX#

BTX? BTX=x

(see description of
arguments)

Rx BERT
State

BRX=

1 byte, value
of 0 or 1

Command or Query.
Rx BERT State, where:
0=Off
1=On

Example: BRX=1 (Rx BERT On)

BRX=
BRX?
BRX*
BRX#

BRX? BRX=x

(see description of
arguments)

Advertising