MN/SLM5650.IOM

B–13

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Tx Clock
Invert

TCI=

1 byte, value
of 0 or 1

Command or Query.
Invert Transmit Clock, where:

x=Invert Transmit Clock, where:
0=Normal
1=Inverted

Example: TCI=1 (selects Inverted TX Clock)

TCI =
TCI?
TCI*
TCI#

TCI? TCI=x

(see description of
arguments)

Tx Data Invert

TDI=

1 byte, value
of 0 or 1

Command or Query.
Invert Transmit Data, where:

x=Invert Transmit Data, where:
0=Normal
1=Inverted

Example: TDI=1 (selects Inverted TX Data)

TDI =
TDI?
TDI*
TDI#

TDI? TDI=x

(see description of
arguments)

Tx Data Fault

TDF=

1 byte, value
of 0 thru 2

Command or Query.
Transmit Data Fault, where:

x=Transmit Data Fault, where:
0=None
1=DATA
2=AIS

Example: TDF=0 (selects Data Fault = None)

TDF =
TDF?
TDF*
TDF#

TDF?

TDF=x
(see description of
arguments)

Tx BPSK
Data Ordering

TBO=

1 byte, value
of 0 or 1

Command or Query.
Invert Transmit BPSK Data Ordering, where:

x=Invert Transmit BPSK Data Ordering, where:
0=Normal
1=Inverted

Example: TBO=1 (selects Inverted BPSK Ordering)

TBO =
TBO?
TBO*
TBO#

TBO?

TBO=x
(see description of
arguments)