Select: config: receive: datarate, Select: config: receive: overhead – Mocomtech SLM-5650 User Manual

Page 83

Advertising
background image

SLM-5650 Satellite Modem

Revision 2

Front Panel Operation

MN/SLM5650.IOM

4–13

Select: CONFIG: Receive: DataRate




The user can enter the desired data rate using step 1 or step 2 as follows:

1. Use the number keypad and enter the desired data rate (see Chapter 3).
2. Use

the

efbc

arrow keys to scroll up and down to select the desired data

rate or symbol rate. When scrolling data rate the symbol rate will be
automatically recalculated and displayed.


IMPORTANT

When entering the data rate, the following interactions need to be taken
into account. If the modulation type selected is 8-PSK or 16-QAM the
minimum data rate allowed is 256 kbps. When changing certain
parameters like modem type, the data rate will default to 64 kbps or 256
kbps. The calculated symbol rate is displayed for the user. This is
helpful for determining the occupied bandwidth required for the
selected
modulation type, code rate and overhead.

Select: CONFIG: Receive: Overhead



Select the desired Overhead, Rate, RS-CW, and Depth and then press [E].

Overhead

(IESS-308, IESS-309 are standard), (AUPC is optional)

Rate

96 kbps (IESS-308), 1/15 (IESS-309 or AUPC), N/A (none)

RS-CW

126/112, 194/178, 208/192, 219/201, 220/200, 225/205
(Reed Solomon Code Rate, N/K)

Depth

4, 8 or 16 (Deinterleaving depth)

IMPORTANT

Some selections will only be visible if the modem is set to a compatible
mode or if an option is installed or enabled.







Rx Data Rate: 020000.000 kbps

Sym Rate: 0266666.666 ksps (

efbcE)

Rx: Overhead:None Rate: N/A

RS-CW:N/A

Depth:N/A (

efE)

Advertising