Tx
Reed-Solomon
Interleaver
Depth

TRD=

1 byte, value
of 0 to 2

Command or Query.
Tx RS encoding
0 = Interleaver Depth 4
1 = Interleaver Depth 8
2 = Interleaver Depth 16

Depending on Modem mode, overhead type, and data rate, not all
of these selections will be valid.

Example: TRD=0 (This is a ‘don’t care’ if RS is Off under TRS)

TRD =
TRD?
TRD *
TRD #

TRD?

TRD =x
(see description of
arguments)

Tx Spectrum
Invert

TSI=

1 byte, value
of 0 or 1

Command or Query.
Tx Spectrum Invert selection, where:
0=Normal,
1=Tx Spectrum Inverted

Example: TSI=0 (which is normal)

TSI=
TSI?
TSI*
TSI#

TSI?

TSI=x
(see description of
arguments)

Tx Scrambler

TSC=

1 byte, value
of 0 thru 6

Command or Query.
Tx Scrambler state, where:
0 = Off
1 = OM-73 Scrambler
2 = V.35 Scrambler
3 = Modified V.35 (EFData Closed Network)
4 = Reed-Solomon Synchronous Scrambler
5 = IBS Overhead Synchronous Scrambler
6 = TURBO Scrambler

Depending on Modem mode, FEC type, overhead type, and RS
state, not all of these selections will be valid.

Example: TSC=1 (OM-73 Scrambler On)

TSC=
TSC?
TSC*
TSC#

TSC?

TSC=x
(see description of
arguments)