Mocomtech SLM-5650 User Manual

Page 137

Advertising
background image

SLM-5650 Satellite Modem

Revision

1

Remote Control

MN/SLM5650.IOM

B–15

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Demod
type

RMD=

1 byte, value
of 0 thru 4

Command or Query.
Rx Modulation type, where:
0=BPSK
1=QPSK
2=OQPSK
3=8PSK
4=16QAM

Depending on FEC type, not all of these selections will be valid.

Example: RMD=1 (which is QPSK)

RMD=
RMD?
RMD*
RMD#

RMD?

RMD=x
(see description of
arguments)

Rx FEC Code
Rate

RCR=

1 byte, value
of 0 thru 8

Command or Query
Rx FEC Code Rate, where:
0 = 1/1 (Uncoded)
1 = 1/2
2 = 3/4
3 = 7/8
4 = 2/3
5 = 5/6
6 = 21/44
7 = 5/16
8 = 17/18

Depending on FEC type, not all of these selections will be valid.

Example: RCR=1 (which is Rate 1/2)

RCR=
RCR?
RCR*
RCR#

RCR?

RCR=x
(see description of
arguments)

Rx Data Rate

RDR=

10 bytes

Command or Query.
Rx Data rate, in kbps.

Resolution=1 bps.

Example: RDR=002047.999 (which is 2047.999 kbps)

N/A

RDR?

RDR=xxxxxx.xxx
(see description of
arguments)



Priority System = MOM (Highest priority), RFB, ITF, RFM, RFT, RMD, RCR, and RDR (Lowest Priority), indicated by shading. Any change to
a higher priority parameter can override any of the parameters of lower priority.