SLM-5650 Satellite Modem

Revision 1

Remote Control

MN/SLM5650.IOM

B–34

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

AUPC
Minimum
Power Level

AMN=

5 bytes

Command or Query.

Minimum Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.

Example: AMN=-13.4

AMN=
AMN?
AMN*
AMN#

AMN? AMN=sxx.x

(see description of
arguments)

AUPC Eb/N0
Target Set
Point

AET=

4 bytes

Command or Query.

AUPC Eb/N0 Target, where:
xx.x = AUPC Eb/N0 Target, 3.2 to 16.0 dB.

Example: AET=13.4

AET=
AET?
AET*
AET#

AET? AET=xx.x

(see description of
arguments)

AUPC
Maximum
Tracking Rate

AMT=

3 bytes

Command or Query.

AUPC Maximum Tracking Rate, where:
x.x = Maximum Tracking Rate, 0.5 to 6.0 dBm/minute in
increments of .5.

Example: AMT=0.5

AMT=
AMT?
AMT*
AMT#

AMT? AMT=x.x

(see description of
arguments)

AUPC Local
Carrier Loss
Action

LCL=

1 byte, values
of 0 thru 2

Command or Query.

Tx Output Power level setting when local carrier is lost, where:
0=Hold current output power level
1=Goto Nominal output power level
2=Goto Maximum output power level

Example: LCL=0

LCL=
LCL?
LCL*
LCL#

LCL? LCL=x

(see description of
arguments)

AUPC Remote
Carrier Loss
Action

RCL=

1 byte, values
of 0 thru 2

Command or Query.

Tx Output Power level setting when remote carrier is lost, where:
0=Hold current output power level
1=Goto Nominal output power level
2=Goto Maximum output power level

Example: RCL=0

RCL=
RCL?
RCL*
RCL#

RCL? RCL=x

(see description of
arguments)