Mocomtech SLM-5650 User Manual

Page 154

Advertising
background image

SLM-5650 Satellite Modem

Revision 1

Remote Control

MN/SLM5650.IOM

B–32

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Receive T2
Framing

T2F=

1 byte, value
of 0, 1, 3, or 5

Command or Query.

Receive T2 Framing, where:
0=None
1=G.704
3=G.743
5=G.747

Example: T2F=0

T2F=
T2F?
T2F*
T2F#

T2F? T2F=x

(see description of
arguments)

Receive E2
Framing

E2F=

1 byte, value
of 0, 1, 2, or 4

Command or Query.

Receive E2 Framing, where:
0=None
1=G.704
2=G.742
4=G.745

Example: E2F=0

E2F=
E2F?
E2F*
E2F#

E2F? E2F=x

(see description of
arguments)

External
Buffer Clock
Reference

ERF=

1 byte, value
of 0 thru 3

Command or Query.

External Buffer Clock Reference, where:
0=External Clock equals Rx Data Rate
1=5 MHz External Clock
2=10 MHz External Clock
3=20 MHz External Clock

Example: ERF=0

ERF=
ERF?
ERF*
ERF#

ERF? ERF=x

(see description of
arguments)