Mocomtech SLM-5650 User Manual

Page 140

Advertising
background image

SLM-5650 Satellite Modem

Revision 1

Remote Control

MN/SLM5650.IOM

B–18

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Clock
Invert

RCI=

1 byte, value
of 0 or 1

Command or Query.
Invert Receive Clock, where:
x=Invert Receive Clock, where:
0=Normal
1=Inverted

Example: RCI=1 (selects Inverted RX Clock)

RCI =
RCI?
RCI*
RCI#

RCI?

RCI=x
(see description of
arguments)

Rx Data Invert

RDI=

1 byte, value
of 0 or 1

Command or Query.
Invert Receive Data, where:
x=Invert Receive Data, where:
0=Normal
1=Inverted

Example: RDI=1 (selects Inverted RX Data)

RDI =
RDI?
RDI*
RDI#

RDI?

RDI=x
(see description of
arguments)

Rx Data Fault

RDF=

1 byte, value
of 0 thru 2

Command or Query.
Receive Data Fault, where:

x= Receive Data Fault, where:
0=None
1=DATA
2=AIS

Example: RDF=0 (selects Data Fault = None)

RDF =
RDF?
RDF*
RDF#

RDF?

RDF=x
(see description of
arguments)

Rx BPSK
Data Ordering

RBO=

1 byte, value
of 0 or 1

Command or Query.
Invert Receive BPSK Data Ordering, where:

x=Invert Receive BPSK Data Ordering, where:
0=Normal
1=Inverted

Example: RBO=1 (selects Inverted BPSK Ordering)

RBO =
RBO?
RBO*
RBO#

RBO?

RBO=x
(see description of
arguments)

Rx Demod
Acquisition
Sweep Range

RSW=

8 bytes

Command or Query.
Rx acquisition sweep range of demodulator, in kHz, ranging from 0
to 60 kHz.

Example: RSW=0060.000 (selects 60 kHz)

RSW=
RSW?
RSW*
RSW#

RSW?

RSW=xxxx.xxx
(see description of
arguments)

Advertising