Mocomtech SLM-5650 User Manual

Page 143

Advertising
background image

SLM-5650 Satellite Modem

Revision

1

Remote Control

MN/SLM5650.IOM

B–21

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx BERT
Reset

BRS= None

Command

only.

Reset Rx BERT

Example: BRS=

BRS=
BRS?
BRS*
BRS#

N/A N/A

Rx BERT
Errors

N/A

7 bytes

Query only.
Read the total number of Bit Errors.

Example: ERR=9999999

N/A ERR? N/A

Rx BERT
BER

N/A

6 bytes

Query only.
Unit returns the value of the BERT BER in the form a.b x 10

-c

. First

three bytes are the value. Last two bytes are the exponent. Returns
0.0E00 if the BERT is not synchronized to a pattern.

Example: BBR=4.9E12

N/A BBR? BBR=a.bEcc

(see description of
arguments)

BERT Pattern

PAT=

1 byte, value
of 0 thru 8

Command or Query.
BERT Pattern, where:
0=2047
1=Mark
2=Space
3=1:1
4=1:3
5=2^15-1
6=2^20-1
7=2^23-1
8=MIL-188

Example: PAT=0 (2047 Pattern)

PAT=
PAT?
PAT*
PAT#

PAT? PAT=x

(see description of
arguments)

Insert Tx
BERT Error

BEI= None

Command

only.

Insert single bit error in Tx BERT

Example: BEI=

BEI=
BEI?
BEI*
BEI#

N/A N/A

Circuit ID
String

CID=

24 bytes

Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed
length of 24 characters.
Valid characters include:
Space ( ) * + – , . / 0 9 and A thru Z

CID=
CID?
CID*
CID#

CID? CID=x

(see description of
arguments)