Mocomtech SLM-5650 User Manual

Page 90

Advertising
background image

SLM-5650 Satellite Modem

Revision 2

Front Panel Operation

MN/SLM5650.IOM

4–20

Select: CONFIG: Remote: Remote: Serial: Interface

If

Interface was selected:




Select

RS232, RS485-2W (2-wire), or RS485-4W (4-wire), or TTL (Switching)

using

the

arrow keys, then press [E]. The TTL (Switch) selection enables

interoperation with the CRS-311 (1:1) or CRS-300 (1:N) switch.


IMPORTANT

When selecting RS-232 the local M&C bus address displays, 0000.
Addressing is not supported by RS-232 or TTL (Switch)because they
are not a multi drop communication standards. If RS-485 is selected,
the display will show address 0001. This address can be changed
using the front panel. The most significant digit is for Comtech EF
Data redundancy switches.

Select: CONFIG: Remote: Remote: Serial: Interface: Baudrate

If Baudrate was selected:




IMPORTANT

The only asynchronous character format supported is 8 bits data, No
parity and 1 stop bit.

M&C Bus Interface: RS232 RS485-2W

RS485-4W TTL (Switching) (

efE)

Local M&C Bus Address:
0000

Local M&C Bus Baud Rate:

38400 Baud

(

bcE)