SLM-5650 Satellite Modem

Revision 1

Remote Control

MN/SLM5650.IOM

B–24

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Local/Remote
Status

LRS=

1 byte, value
of 0 or 1

Command or Query.
Local/Remote status, where:
0=Local
1=Remote

Example: LRS=1 (which is Remote)

LRS=
LRS?
LRS*
LRS#

LRS? LRS=x

(see description of
arguments)

Software
Revision

N/A

43 bytes

Query only.
Unit returns the value of the internal software revision installed in
the unit, in the form:
Boot:xx.yy.zz Bulk1:xx.yy.zz Bulk2:xx.yy.zz

Example: SWR=Boot:01.01.01 Bulk1:01.01.01 Bulk2:01.01.01

N/A SWR?

SWR=Boot:xx.yy.zz
Bulk1:xx.yy.zz
Bulk2:xx.yy.zz
(see description
of arguments)

Software
Image

IMG=

1 bytes, value
of 1 or 2

Command or Query.
Current Active software image, where:
1 = Bulk Image #1 currently active
2 = Bulk Image #2 currently active

Example: IMG=1 (which is Image #1 active)

IMG=
IMG?
IMG*
IMG#

IMG? IMG=x

(see description of
arguments)

Serial Number

N/A

9 bytes

Query only.
Used to query the unit 9-digit serial number. Unit returns its S/N in
the form xxxxxxxxx.

Example: SNO=176500143

N/A SNO? SNO=xxxxxxxxx

(see description of
arguments)

Temperature

N/A

3 bytes

Query only.
Unit returns the value of the internal temperature, in the form of xxx
(degrees C).

Example: TMP=+26

N/A TMP? TMP=xxx

(see description of
arguments)

Advertising