8 summary of specifications – Mocomtech SLM-5650 User Manual

Page 28

Advertising
background image

SLM-5650 Satellite Modem

Revision 2

Introduction

MN/SLM5650.IOM

1–8

1.8

Summary of Specifications

Table 1-1. Summary of Specification

Parameter

Specification

Operating Frequency Range

52 to 88, 104 to 176, 950 to 2000 MHz,
in 100 Hz steps

Modulation Types

BPSK, QPSK, OQPSK, 8-PSK, 16-QAM

Digital Data Rates

64 kbps to 5 Mbps, in 1 bps steps (EIA-530, EIA-613)
64 kbps to 10 Mbps, in 1 bps steps (EIA-530, EIA-613)
64 kbps to 20 Mbps, in 1 bps steps (EIA-530, EIA-613)
64 kbps to 51.840 Mbps, in 1 bps steps (EIA-613)

Symbol Rate Range

32 K

S

/

S TO

30 M

S

/

S

EXT REF Input

TNC Connector, 1, 5, or 10 MHz selectable

INT REF Stability

1 x 10

-7

Scrambling

V.35, OM-73, and Synchronous

IDR/IBS Framing Compatibility

Support for IBS and IDR framing. Allows basic IBS/IDR Open
Network capable operation.

Built-in Test (BIT)

Fault and status reporting, BER performance monitoring, IF
Loop-back, programmable test modes, built in Fireberd
emulation with all comprehensive BER measurements.

Summary Faults

Reported via Front Panel LEDs, 9-pin D sub Alarm connector,
relay contacts for Tx, Rx, Common equipment faults, and Tx
and RX alarms. Open collector faults on the 15-pin D sub Aux
connector. Both data interfaces have open collector faults
available.

Monitor and Control

EIA-485, EIA-232, 10/100 BASET Ethernet with HTTP, Telnet,
and SNMP.

Modulator Specification
Output Power

+10 – 40 dBm, adjustable in 0.1 dB steps

Output Return Loss

-14 dB (70/140 MHz)
-9 dB (L-Band)

Output Impedance

50

Ω

Spurious

From Carrier

±

T

X

SR

TO

500 MH

Z

–51 dBc (measured in a

10 kHz bandwidth)

Harmonics

From Carrier (CW) to the greater of the 12

th

harmonic or

4000 MHz –60 dBc

Tx Clock Source

Rx, INT, Tx Terrestrial, and Data Source Sync

Output Connections

TNC for 52 to 88, 104 to 176 MHz
Type N for 950 to 2000 MHz

Modulation Timing Jitter

< 3

% of the modulation symbol period.

Modulation Phase Error

< 2

°

Modulator Spectral Inversion

Modem can invert the modulated spectrum

Transmit Clock and Data
Inversion

Modem can invert the Tx clock and data independently of each
other. (EIA-530, EIA-613)

Advertising