Mocomtech SLM-5650 User Manual

Page 165

Advertising
background image

SLM-5650 Satellite Modem

Revision 1

Reflash

MN/SLM5650.IOM

C–3

Verify the communication and connection by issuing a "ping" command to the
modem. You can find the IP address of the modem either remotely using the
<0/IPA? command or from the front panel with the <Config> <Remote> <Remote>
<Ethernet> menus.

To PING and FTP from DOS, press the “Start” button on the Windows toolbar, and
select the “Run...” option. From Win95 or Win98, type, “command”. From WinNT,
Win2K or WinXP, type “cmd”. You can also use the “DOS Prompt” or “Command
Prompt” icons in the Start Menu. Now change to the temporary directory you
created earlier with “cd c:\temp”. A quick “dir” will show the downloaded files.

6. Initiate an FTP session with the modem. The example is with a DOS window.


a. From the PC, type "ftp xxx.xxx.xxx.xxx" where "xxx.xxx.xxx.xxx" is the IP

address of the SLM-5650.


b. Enter your admin user name and password to complete login.

Factory Default user is: COMTECH

Password

is:

COMTECH


c. Verify your FTP transfer is binary by typing, "bin".

d. Type "prompt" then type "hash" to facilitate the file transfers.

7. Transfer the files.


Type "put FW11188*.bin bulk:" to begin the file transfers. The destination “bulk:”
must be all lower-case. It will take approximately one minute to transfer the file.

8. Verify the file transfer.


a. The PC should report that the file transfer has occurred, and the display on the

modem will start reporting “PROGRAMMING FLASH SECTOR # xx –
PLEASE WAIT”.


b. Terminate the FTP session by typing "bye" and closing the DOS window.

c. Verify that the new file loaded using the procedure in step 1.







9. Change the desired image to boot using the <Util> <Firmware> <Select> <left or right

arrow to change to the other image>, then cycle power to reboot the modem.

Advertising