W-2WAY ECO-i SYSTEM Unit Specifications

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

4. Concealed Duct Type (U Type)

Indoor unit (E)

MODEL No.

UHX3652

Power source

208 - 230 V / 1ø / 60 Hz

Controller P.C.B. Ass'y

CR-UXRP71B-B (Microprocessor)

Fan...(Number diameter / length in. (mm))

Centrifugal (1 ... ш7-31/64 (ш190))

Fan motor

Model...Nominal output

W

KFC4X-141A6P...140W

Power source

208 - 230 V / 1ø / 60 Hz

No. of pole...r.p.m. (230V, High)

rpm

4P... 1,207

Coil resistance
(Ambient temperature 68°F)

BRN – WHT : 39.94

ORG – YEL : 8.857

WHT – VLT : 6.911

YEL – BLK : 8.857

VLT – ORG : 11.44

BLK – PNK : 14.29

Run capacitor

VAC, µF

450 VAC, 6.0 µF

Safety device

fuse

Operating temperature

Open °F (°C)

266 ± 9 (130 ± 5)

Close °F (°C)

168 ± 27 (76 ± 15)

Electronic expansion valve

Coil

UKV-U031E

Coil resistance (at 68°F)

ORG – GRY : 46

YEL – GRY : 46

RED – GRY : 46

BLK – GRY : 46

Valve body

UKV-30D33

Heat exchanger

Coil

Aluminum plate fin / Copper tube

Rows...fin pitch

in. (mm)

3...5 / 64 (2.0)

Face area

ft

2

(m

2

)

3.32 (0.308)

Drain pump

PLD-12230ST

Rated

V, Hz, W

AC230V, 60Hz, 10.8W

Total head & capacity

in. (mm), gal/

min (cc/min)

19-11 / 16 (500), 0.11 (400)