As-interface slaves – Siemens ISI EN 50295 User Manual

Page 109

Advertising
background image

Siemens IK PI · 2004

6/109

AS-Interface Slaves

AS-Interface motor starters and IP65/67 load feeders

AS-Interface compact starters IP65 (400 V AC)

6

Technical specifications

DS/RS

EDS/ERS

Degree of protection

IP65 (with covered connecting elements and cover flap)

Material

Thermoplastic (glass-fibre reinforced)

Color

Anthracite RAL 7016

Cover flap

Latching, sealable

Dimensions (W x H x D) in mm

120

´ 265 ´ 134

Temperature range

• Operating temperature in °C

-25 to +55 (derating must be observed: See manual)

• Storage temperature in °C

-40 to +70

Permissible service position

Shock resistance

Rectangular pulse (g/ms)

2/unlimited, 10/5 or 5/10

Sine pulse (g/ms)

2/unlimited, 8/10 or 15/5

External voltage supply

For output supply (contactor activation)
Rated operational voltage U

e

in V

DC 24 (PELV; must be earthed)

For electronics and inputs (acknowledgements
of switchgear status) via AS-Interface data
cable in V

DC 26.5 to 31.6 (in compliance with AS-Interface specification)

I/O configuration (hex)

7

ID code (hex)

D

E

Power consumption of AS-Interface in mA

Max. 100

Current input U

Aux

in mA

Approx. 100

Watchdog
(shutdown of outputs in case of AS-Interface
fault)

Built-in

Diagnostics

Via AS-Interface

Checkback signal from circuit-breaker and contactor(s)
via positively-driven auxiliary contacts and separate inputs

Via LED at the housing

Auxiliary voltage applied
AS-Interface communication OK
AS-Interface communication faulty
Station address = 0 (module not addressed)

Via LED at the hand-held terminal

ON or clockwise rotation or anti-clockwise rotation

Main circuit

Rated operational voltage

500 V AC to DIN VDE 0106 Part 101, AC 600 V to CSA and UL

Safety separation between main and auxiliary
circuit (to DIN VDE 0106, Part 101)

up to 400 V

-

Rated output

5.5 kW

2.2 kW

Permissible operating duties

Uninterrupted duty, temporary duty, periodic duty, intermittent periodic duty
(50 % rel. ON-time at 80 operations/h at 5.5 kW)

Permissible operating frequency for a starting
time t

A

= 0.1 s and a rel. ON period t

EP

= 50 %

£ 80 1/h

£ 600 1/h

Trip class

Class 10

Conductor cross-section for power connector
incoming supply/ feeder/ looping through 9-
pole

£ 4 mm

2

, AWG 15-11

Max. perm. current via power connector
(dependent on cable cross-section)

T

u

= 60 °C

30 A (4 mm

2)

, AWG (11); 20 A (2.5 mm

2)

), AWG (15); 12 A (1.5 mm

2

), AWG (13)

T

u

= 40 °C

35 A (4 mm

2)

, AWG (11); 25 A (2.5 mm

2

), AWG (15); 15 A (1.5 mm

2

), AWG (13)

Short-circuit strength of starter combination
in kA

50 (to type of co-ordination "1")

100

Electrical endurance of the circuit-breaker
component for a load I

a

(AC-3)

See service-life characteristics for 3RT10 contac-
tors

³ 10 million operating cycles

N

S

A

0_

00

10

4

2 2 , 5 ° 2 2 , 5 °

9 0 °

9 0 °