Siemens IK PI · 2004

6/3

AS-Interface

Introduction

Configuration examples

6

■

Function

Operating modes

In general, the master interfaces distinguish between the follow-
ing operating modes:

I/O data transfer

The inputs and outputs of the binary AS-Interface slaves are
read and written in this operating mode.

Analog value transmission

The AS-Interface masters according to the Complete
AS-Interface Specification V2.1 support integrated analog value
processing. This means that data exchange with analog

AS-Interface slaves (according to analog profile 7.3 or 7.4) is just
as easy as with digital slaves.

Command interface

In addition to the I/O data exchange with binary and analog AS-
Interface slaves, the AS-Interface masters offer a range of addi-
tional functions through the command interface.
This means that, from user programs, slave addresses can be
assigned, parameter values can be transferred and diagnostic
information can be read out.

■

Design

Process or field communication

AS-Interface is used wherever individual actuators and sensors
are physically distributed throughout the machine (e.g. in a bot-
tling plant or on a production line).
AS-Interface replaces complicated wiring harnesses and con-
nects binary and analog actuators and sensors, such as proxim-
ity switches, valves or indicator lights, to a controller (e.g. SI-
MATIC) or PC.

In practice this means: The installation runs without problems
because data and power are transported through a single com-
mon cable. No specialist know-how is required for installation
and startup. In addition, the simple installation and clear struc-
turing of the wiring and special cable design not only consider-
ably reduce the risk of faults but also reduce service and main-
tenance costs.

Example of a system configuration

G_IK10_XX_20027

Connection via AS-Interface cable

AS-Interface distributor

(without AS-Interface chip)

AS-Interface cable

AS-Interface

power section

Branch M12

K60

AS-Interface distributor

(without AS-Interface chip)

Repeater

LOGO!

Operator panel

K45

(with AS-Interface chip)

for connection of

standard sensors

Standard encoders

e.g. position switches

Standard sensor

e.g. inductive BERO

Compact starter IP 65

max 100 m

SONAR BERO

with int. AS-Interface

AS-Interface

power section