Configuration examples, Configuration example, As-interface – Siemens ISI EN 50295 User Manual

Page 3: Introduction, Connection via as-interface cable

Advertising
background image

Siemens IK PI · 2004

6/3

AS-Interface

Introduction

Configuration examples

6

Function

Operating modes

In general, the master interfaces distinguish between the follow-
ing operating modes:

I/O data transfer

The inputs and outputs of the binary AS-Interface slaves are
read and written in this operating mode.

Analog value transmission

The AS-Interface masters according to the Complete
AS-Interface Specification V2.1 support integrated analog value
processing. This means that data exchange with analog

AS-Interface slaves (according to analog profile 7.3 or 7.4) is just
as easy as with digital slaves.

Command interface

In addition to the I/O data exchange with binary and analog AS-
Interface slaves, the AS-Interface masters offer a range of addi-
tional functions through the command interface.
This means that, from user programs, slave addresses can be
assigned, parameter values can be transferred and diagnostic
information can be read out.

Design

Process or field communication

AS-Interface is used wherever individual actuators and sensors
are physically distributed throughout the machine (e.g. in a bot-
tling plant or on a production line).
AS-Interface replaces complicated wiring harnesses and con-
nects binary and analog actuators and sensors, such as proxim-
ity switches, valves or indicator lights, to a controller (e.g. SI-
MATIC) or PC.

In practice this means: The installation runs without problems
because data and power are transported through a single com-
mon cable. No specialist know-how is required for installation
and startup. In addition, the simple installation and clear struc-
turing of the wiring and special cable design not only consider-
ably reduce the risk of faults but also reduce service and main-
tenance costs.

Example of a system configuration

G_IK10_XX_20027

Connection via AS-Interface cable

AS-Interface distributor

(without AS-Interface chip)

AS-Interface cable

AS-Interface

power section

Branch M12

K60

AS-Interface distributor

(without AS-Interface chip)

Repeater

LOGO!

Operator panel

K45

(with AS-Interface chip)

for connection of

standard sensors

Standard encoders

e.g. position switches

Standard sensor

e.g. inductive BERO

Compact starter IP 65

max 100 m

SONAR BERO

with int. AS-Interface

AS-Interface

power section