As-interface, As-interface safety at work – Siemens ISI EN 50295 User Manual

Page 12

Advertising
background image

Siemens IK PI · 2004

6/12

AS-Interface

AS-Interface safe compact modules

AS-Interface Safety at work

6

Technical specifications (continued)

Outputs

• Type of output

--

Electronics

Electronics

• Current carrying capacity

DC 12/13 in A

--

2

--

• Current carrying capacity typ.

(max. 4 A per module) in A

--

Max. 0.18

Max. 4

• Pin assignment outputs

--

3 = "–"
4 = Output
5 = Earth connection

3 = "–"
4 = Output
5 = Earth connection

• Short-circuit protection

--

Built-in

Built-in

• Inductive interference protec-

tion (free-wheeling diode)

--

None

Built-in

• External voltage supply

24 V DC

--

--

Via black AS-Interface flat cable

• Watchdog

--

Built-in

Built-in

I/O configuration

0

7

7

ID/ID2 code

B

B

B

Assignment of data bits

• Socket 3 and 4

Not assigned (closed)

Not assigned (closed)

Not assigned (closed)

• Socket 5

Not assigned (closed)

Pin 4 = OUT1 (D0)
Pin 2 = Not assigned (closed)

Pin 4 = OUT1 (D0)
Pin 2 = Not assigned (closed)

• Socket 6

Not assigned (closed)

Pin 4 = OUT2 (D1)
Pin 2 = Not assigned (closed)

Pin 4 = OUT2 (D1)
Pin 2 = Not assigned (closed)

• Socket 7 and 8

Not assigned (closed)

Not assigned (closed)

Not assigned (closed)

AS-Interface certificate

Yes

Yes

Yes

Approvals

UL, CSA

UL, CSA

UL, CSA

Degree of protection

IP67

IP67

IP67

Earth connection

--

PIN 5 of each M 12 socket is
connected to the grounding plate in
the mounting plate via a pin
(outputs only sockets 5 and 6).

PIN 5 of each M 12 socket is
connected to the grounding plate in
the mounting plate via a pin
(outputs only sockets 5 and 6).

Ambient temperature in °C

-25 to +85

-25 to +85

-25 to +85

Storage temperature in °C

-40 to +85

-40 to +85

-40 to +85

Number of I/O sockets

2

4

4

Status indication

• I/O display

Yellow LED

Yellow LED

Yellow LED

U

Aux

--

--

Green LED

• AS-Interface/diagnostics

display

Green/red LED

Green/red LED

Green/red LED

Connection

via mounting plate for K45 compact
module

via mounting plate for K60 compact
module

via mounting plate for K60 compact
module

Addressing

Front addressing socket,
after the 15th addressing,
the module keeps the last address

Front addressing socket,
after the 15th addressing,
the module keeps the last address

Front addressing socket,
after the 15th addressing,
the module keeps the last address