As-interface slaves, As-interface motor starters ip67 (24 v dc) – Siemens ISI EN 50295 User Manual

Page 114

Advertising
background image

Siemens IK PI · 2004

6/114

AS-Interface Slaves

AS-Interface motor starters IP67 (24 V DC)

AS-Interface motor starters and IP65/67 load feeders

6

Technical specifications

Single direct on-line starter

Double direct on-line starter

Single reversing starter

4 inputs

4 inputs

4 inputs

1 output

2 outputs

1 output

Quickstop function
3RK1 400-1NQ01-0AA4

3RK1 400-1MQ01-0AA4

3RK1 400-1MQ03-0AA4

Slave type

Standard slaves

Operational voltage in accordance
with AS-Interface specification in V

26.5 to 31.5

Total current input from AS-Interface
in mA

£ 270

Input connection

PNP

Inputs

• Sensor supply via AS-Interface

Short-circuit and overload proof

• Sensors

3-wire

• Voltage range in V

20 to 30

• Load rating for sensor supply

in mA

200 (T

u

£ 40 °C) / 150 (T

u

£ 55 °C)

• Switching level High in V

³ 10

• Switching level Low in V

£ 5

• Socket assignment

PIN 1 = Sensor supply L+
PIN 2 = Data input
PIN 3 = Sensor supply L-
PIN 4 = Data input/Quickstop
PIN 5 = Earth connection

• External voltage supply DC 24 V

Via black AS-Interface flat cable

• Max. start-up ramp time for DC

motor in ms

80

• Max. motor start-up current

(internally limited) in A

4.5

Outputs

• Type of output

Electronics

• Nominal load rating per output in A 3 (T

u

£ 55 °C)

-

1 x 3 (T

u

£ 55 °C)

2 x 2 (T

u

£ 55 °C)

2.5 (T

u

£ 55 °C)

-

• Max. total current in A

-

4

-

• Voltage drop (without incoming

line) in V

0.6

1.2

• Short-circuit protection

Built-in

• Inductive interference protection

(free-wheeling diode)

Built-in

• Watchdog

Built-in

I/O configuration

7

ID code

F

Assignment of data bits

• Socket 1

PIN4 = IN1 (D0 / Quickstop1)
PIN2 = IN2 (D1)

• Socket 2

PIN4 = IN3 (D2)
PIN2 = IN4 (D3)

PIN4 = IN3 (D2 / Quickstop2)
PIN2 = IN4 (D3)

• Socket 3

PIN4 = OUT1(D0)

PIN4 = OUT1(D0)

PIN2,4 = OUT1 (D0, D1)

• Socket 4

-

PIN4 = OUT2(D1)

-

AS-Interface certificate

Yes

Approvals

UL, CSA

Degree of protection

IP67

Earth connection

Yes

Ambient temperature in °C

-25 to +55

Storage temperature in °C

-40 to +85

Number of I/O sockets

3

3

Note

Max. switching frequency when
activating, e. g. a 10 W DC motor
(U

Aux

= 28.8 V/duty cycle = 50 %):

Tu

max

/°C: 55

• Max. switching frequency/h: 1500

Max. switching frequency when
activating, e. g. a 10 W DC motor
(U

Aux

= 28.8 V/duty cycle = 50 %):

Tu

max

/°C: 55

• Max. switching frequency/h: 1500

Max. switching frequency when
activating, e. g. a 10 W DC motor
(U

Aux

= 28.8 V/duty cycle = 50 %):

Tu

max

/°C: 55

• Max. switching frequency/h: 1000

Advertising