Amount of fuel flow – Kawasaki STX-15F User Manual

Page 134

Advertising
background image

3-80 FUEL SYSTEM (DFI)

Fuel Line

•

Prepare a measuring cylinder [A].

•

Disconnect the fuel supply hose from the fuel delivery
pipe, and set the measuring cylinder and fuel supply hose
[B] as shown.

•

Close the fuel tank cap.

WARNING

Wipe off spilled out fuel immediately.
Be sure to hold the measuring cylinder vertical.

•

Turn the ignition switch ON.

•

Push the start button for 3 seconds.

•

Measure the discharge for 3 seconds.

Amount of Fuel Flow

Standard: 67 mL or more for 3 seconds

If the fuel flow is much less than the specified, check the
following:

Fuel Hose from Fuel Pump Supply Pipe to Fuel Filter for
Sharp Bend, Kinking, or Clogging
Fuel Pump Operation (see Fuel Pump Operation Inspec-
tion)
Fuel Pump Screen (see Fuel Pump Screen Cleaning)

If above inspection checks out good, replace the fuel
pump, and measure the amount of fuel flow again.

•

After inspection, connect the fuel hose.

•

Start the engine and check for fuel leakage.

○

For JT1500-A2 model

∼

; Replace the double spring

clamps with new ones. (see Fuel System Diagram)

Advertising