14-34 ELECTRICAL SYSTEM

Charging System

Tighten:

Torque - Regulator/rectifier Bolts: 7.8 N·m (0.80 kgf·m, 69

in·lb)

When installing the bracket, apply a non-permanent lock-
ing agent to the bracket mounting screws and tighten
them securely.

Regulator/Rectifier Inspection

With the hand tester set to the R × 1 kΩ range, test the
regulator/rectifier according the following table.

Special Tool - Hand Tester: 57001-1394

Regulator/Rectifier Inspection

Unit: kΩ

Tester (+) Lead Connection

Terminal

+

+

500

∞ 500

∞ 500

∞ 500

(–)*

2

20

500

∞ 500

∞ 500

2

20

500

500

∞ 500

2

20

500

∞ 500

500

2

40

2

20

2

20

2

20

(–)*: Tester (–) lead Connection
If any of the values obtained do not agree with the above
table, the regulator/rectifier must be replaced.

Regulator Inspection

To test the regulator out of circuit, use three 12 V batteries
and a test light (12 V 3

6 W bulb in a socket with leads).

CAUTION

The test light works as an indicator and also as a
current limiter to protect the regulator/rectifier from
excessive current. Do not use an ammeter instead
of a test light.

Do the 1st step regulator circuit test.

Connect the test light and the 12 V battery to the regula-
tor/rectifier as shown.

Check infinity (

) terminals respectively.

If the test light turns on, the regulator/rectifier is defective.
Replace it.
If the test light does not turn on, continue the test.