Pump and Impeller

Impeller Outside Diameter Measurement

•

Measure the impeller outside diameter.
If the impeller is worn smaller than the service limit, re-
place it.

Impeller Outside Diameter

Standard:

147.5

∼

147.7 mm (5.8071

∼

5.8149 in.)

Service Limit: 146.5 mm (5.7677 in.)

Pump Inspection

•

Examine the pump case [A].
If there are deep scratches inside the pump case, replace
it.

○

Measure the inside diameter of the pump case.
If the pump case is worn beyond the service limit, replace
it.

Pump Case Inside Diameter

Standard:

148.0

∼

148.1 mm (5.8268

∼

5.8307 in.)

Service Limit: 149.1 mm (5.8701 in.)

Impeller Clearance

•

Impeller clearance is critical to proper performance. If the
pump case and impeller are not visibly damaged, poor
performance may be caused by too much impeller clear-
ance.

•

To check impeller clearance, remove the grate and insert
a feeler gauge [A] between the tip of the impeller blade
[B] and the pump case [C].

Impeller Clearance

Standard:

0.15

∼

0.3 mm (0.0059

∼

0.0118 in.)

Service Limit: 0.6 mm (0.0236 in.)

If impeller clearance is incorrect, determine if it is due to
wear or damage (see Pump and Impeller Inspection).

Water Filter Cover Removal/Installation

•

Loosen the clamps [A] and pull off the hoses [B].

•

Remove the filter cover mounting bolts [C].

•

Take out the filter cover [D].

•

Replace the gasket with a new one.

•

Installation is the reverse order of removal.

•

Apply a non-permanent locking agent to the filter cover
mounting bolts and torque them.

Torque - Filter Cover Mounting Bolts: 9.8 N·m (1.0 kgf·m,

87 in·lb)