3-27

Wax Lift
Bracket

Wax Lift PCB

Capacitor
PCB

Screws(4)

Nuts(3)

Spacers(3)

Screws(3)

Washers(3)

Life Fitness Model 97Te, 95Te, 97Ti, 95Ti and 93T Arctic Silver Treadmills
How To... Replace the Motor Controller, Wax Lift PCB Bracket, and Capacitor PCB –

(Continued)

Special Service Tools Required: NONE


6. With the Wax Lift Board Assembly out of the Unit, remove the attached Capacitor PCB from the Wax Lift Bracket

for re-use. See the illustration showing exploded parts of the Wax Lift Board.


Note: If the Capacitor is physically damaged or smells burned, then replace it along with the Motor Controller
Assembly.

7. Install New Motor Controller or Wax Lift Board Assembly in reverse order. Make sure to re-install the Capacitor

Board back on the Wax Lift Bracket.


Note: Replace both the capacitor and power control board if they are damaged.