Troubleshooting guide – Life Fitness 93T User Manual

Page 15

Advertising
background image

1-8

Life Fitness Model 97Te, 95Te, 97Ti, 95Ti and 93T Arctic Silver Treadmills

TROUBLESHOOTING GUIDE



SYMPTOM

PROBABLE CAUSE

CORRECTIVE ACTION

Stop Switch is activated with very light
pressure or returns very slowly after
being pressed.

Replace Stop Switch. See How
To…Replace Stop Switch.

Stop switch cable not making proper
contact.

Re-seat cable from stop switch and
verify the operation.

Pinched main wire harness.

Replace the main wire harness. See
How To…Replace Main Wire Harness.

Open ground path.

Using voltmeter, check all points for
continuity: console pan screws,
console mounting screws, handlebar
screws, and handrail mounting screws
to frame with respect to ground.
Ground must be a non-painted
surface.

Unit resets randomly or
pauses.

Inspect Smart Stop system.

Disconnect the 4-pin connector and
verify if problem exists. If no, replace
Smart Stop PCB. See “How To…”
Replace Smart Stop PCB.

Striding belt needs to be re-tensioned
or tracking needs adjustment.

Refer to belt tensioning or tracking
adjustment procedure in operation or
service manual.

Unit is not level.

Refer to the Operation Manual or
Service Manual.

The Striding Belt is
traveling beyond the
tracking limits.

Check to see if the belt barriers are still
in place or damaged.

Contact Life Fitness