SYMPTOM

PROBABLE CAUSE

CORRECTIVE ACTION

Striding belt not centered.

Striding belt tension or tracking needs
to be adjusted.

See How To…Adjust And Tension The
Striding Belt.

Striding belt misalignment,
but properly tensioned.

Improper walking/running.

Notify Club Manager.

Dirty handlebar sensors.

Wipe sensors with a clean soft cloth.
Verify operation. Refer to Diagnostics
in Section 2.

User running over 4.5 mph (7.5kph).

For accurate heart rate reading, user
must slow down to less than 4.5 mph
(7.5kph).

User may have an unusual heart
condition.

Have different people grasp sensors to
detect any variance.

Loose connections at display console
and handlebar.

Secure connections at display console
and handlebar.

Faulty heart rate sensors.

Replace handlebar sensors. See How
To… Replace Heart Rate Kit.

Lifepulse Heart Rate
System does not respond
or improper heart rate
reading or "Reading Heart
Rate" appears in the
message center for more
than 2 minutes without
giving heart rate reading.

Faulty display console PCB.

Replace display console PCB. See
How To… Replace Console PCB.

Display reads a continuous
heart rate reading when
hands are removed.

Harness wires pinched at handlebar or
handrail.

If the wires are damaged, replace
damaged cables. See How
To…Replace Handlebar Assembly.

Chest strap sensors not making good
contact with body of user.

Adjust chest strap and moisten
sensors to make better contact with
skin.

User is out of monitoring range.

Move within 3 ft (1 meter) of receiver

Loose connection at receiver.

Check connection. See “How
To”...Replace Telemetry Receiver.

No Chest Strap detected.

Faulty chest strap.

Replace chest strap.