Lifepulse on/off, Diagnostics: system test – lifepulse, Test – Life Fitness 93T User Manual

Page 44

Advertising
background image

2A-19

Life Fitness Model 97Te, 95Te, 97Ti, 95Ti and 93T Arctic Silver Treadmills

DIAGNOSTICS: SYSTEM TEST – LIFEPULSE

®

TEST





Upon entering the LifePulse

®

test, a heart shape will then appear in the profile window indicating that LifePulse

®

is

ready to acquire a signal.

The system will now sense when either hand is in proper contact with the LifePulse

®

sensors by displaying an "L"

(Left) or "R" (Right) next to the heart in the profile window.

Once the LifePulse

®

system acknowledges that both hands are in place on the sensors and providing the proper

signals, a timer will start. The timer displays acquisition time. Once heart rate data is displayed, the counter will
stop.

ON/OFF

Status of LifePulse

®

feature.

NOTE - This test will not function if the LifePulse

®

feature has been disabled.

GAIN (0-99)

Value displayed is proportional to the amount of signal that is being provided by the LifePulse

®

sensors. The higher the gain values the lower the signal that is being evaluated by the
LifePulse

®

system.

CONfidence (0-9)

Value displayed that indicates a confidence level for heart rate values displayed. Higher
confidence readings indicate that LifePulse

®

is providing accurate readings while low

confidence readings most often indicate poor contact with hand sensors.


Both the speed and incline systems can be adjusted during this test. The display will show this information briefly
when any incline or speed keys have been pressed, and then revert to LifePulse

®

information.


► Press the CLEAR key to exit the LIFEPULSE

®

TEST and return to the SYSTEM TEST Menu.

► Press the CLEAR key multiple times until the message SYSTEM INITIALIZING is displayed to exit diagnostic mode.

LIFEPULSE ON/OFF

L

R