How to... replace the heart rate sensors – Life Fitness 93T User Manual

Page 147

Advertising
background image

3-32

Signal Output
Sensor

Ground
Sensor

Sensor
Screws

Note: Clean before
reassembling

using alcohol

Life Fitness Model 97Te, 95Te, 97Ti, 95Ti and 93T Arctic Silver Treadmills

How To... Replace the Heart Rate Sensors


Special Service Tools Required: NONE

1. Turn the unit power OFF at the

switch then unplug the line cord at
the wall outlet.


2. Remove two screws securing the

Heart Rate Sensors.


3. Disconnect the wire (black or

green) from the Ground Sensor and
the wire (red or white) from the
Signal Output Sensor.


4. Discard the old Sensor.

5. Install new sensors in reverse

order, and tighten with screws 5-7
in lbs.


6. Repeat the above steps for the remaining Heart Rate Sensor.