Troubleshooting Your SoundPoint IP / SoundStation IP Phones

5 - 3

Error, application is not present!

There is no application stored in flash memory and the phone cannot boot. A

compatible SIP application must be downloaded into the phone using one of

the supported provisioning protocols. You need to resolve the issue of

connecting to the boot server. This error is typically a result one of the above

errors. This error is fatal.

Not all configuration files were present on the server

Similarly, a message about configuration files not being present, means that

the phone was able to reach the boot server, but that it was not able to find all

the necessary files. So long as the files exist in flash memory, the phone can

boot following this error.

Error loading <file name>

When the required file does not exist in flash memory and cannot be found on

the boot server, the “Error loading” message will tell you which file could not

be found. This error only remains on the screen for a few seconds so you need

to watch closely. The phone reboots.

Application Error Messages

Config file error. Error is <Hex #>

If there is an error in the configuration file, you will not be able to reboot the

phones. You must review the boot server configuration, make the correction,

and reapply the configuration file by restarting the phones.

Network link is down

Since the SoundPoint IP / SoundStation IP phones do not have an LED

indicating network LINK status like many networking devices, if a link failure

is detected while the phone is running a message saying “Network link is

down” will be displayed. This message will be shown on the screen whenever

the phone is not in the menu system and will remain on screen until the link

problem is resolved.

Note

This error does not occur with the current BootROM.

Note

This error does not occur with the current BootROM.