Miscellaneous Administrative Tasks

C - 27

Disabling PC Ethernet Port

Certain SoundPoint IP phones have a PC Ethernet port. If it is unused, it can

be disabled.
The PC Ethernet port can be disabled on the SoundPoint IP 330, 430, 450, 550,

560, 601, 650, and 670 and 850. The port cannot be disabled on the SoundPoint

IP 301, 501, and 600 due to a lack of hardware support for the feature.

To disable the Ethernet port on a supported SoundPoint IP phone:

1.

Press .

2.

Select Settings > Advanced > Network Configuration > Ethernet Menu.
You must enter the administrator password to access the network

configuration. The factory default password is 456.

3.

Scroll down to PC Port Mode and select Edit.

4.

Select Disabled, and then press the OK soft key.

5.

Press the Exit soft key.

6.

Select Save Config.
The SoundPoint IP phone reboots. When the reboot is complete, the PC

Ethernet port is disabled.