Voice activity detection <vad, A-52, Quality monitoring <quality – Polycom SOUNDPOINT SIP 3.1 User Manual

Page 206: Monitoring, Quality monitoring <quality monitoring

Advertising
background image

Administrator’s Guide SoundPoint IP / SoundStation IP

A - 52

Voice Activity Detection <vad/>

These settings control the performance of the voice activity detection (silence

suppression) feature.

Quality Monitoring <quality monitoring/>

This attribute includes:

Central Report Collector <collector/>

Alert Reports <alert/>

voice.txEq.hf.IP_430.postFilter.enable

1

voice.txEq.hf.IP_500.postFilter.enable

1

voice.txEq.hf.IP_600.postFilter.enable

1

voice.txEq.hf.IP_601.postFilter.enable

1

voice.txEq.hf.IP_650.postFilter.enable

1

voice.txEq.hf.IP_4000.postFilter.enable

0

voice.txEq.hf.IP_6000.postFilter.enable

0

voice.txEq.hf.IP_7000.postFilter.enable

0

Attribute

Default

Attribute

Permitted
Values

Default

Interpretation

voice.vadEnable

0, 1

0

If set to 1, enable VAD.

voice.vadThresh

integer from 0
to 30

15

The threshold for determining what is active voice and
what is background noise in dB. This does not apply to
G.729AB codec operation which has its own built-in VAD
function.

voice.vad.

signalAnnexB

0, 1

Null

If set to 1 or Null and voice.vadEnable is set to 1,
Annex B is used. A new line can be added to SDP
depending on the setting of this parameter and the
voice.vadEnable

parameter.

If voice.vadEnable is set to 1, add attribute line
a=fmtp:18 annexb="yes" below a=rtpmap… attribute
line (where '18' could be replaced by another
payload).

If voice.vadEnable is set to 0, add attribute line
a=fmtp:18 annexb="no" below a=rtpmap… attribute
line (where '18' could be replaced by another
payload).

If set to 0, there is no change to SDP.

Advertising