Table 2 isdn bri card location, Procedures, Procedure 1 selecting the card slots – Nortel Networks NN43001-318 User Manual

Page 16: Procedure 1, Selecting the card slots

Advertising
background image

16

Installing ISDN BRI hardware

4

Install the S/T Interface Linecards (SILCs) and/or U Interface
Linecards (UILCs) or Basic Rate Signaling Concentrators (BRSCs).

5

Connect ISDN BRI terminals. This procedure comprises the
following:

Connect the system to the Main Distribution Frame (MDF).

Cross-connect the MDF.

Connect ISDN BRI terminals to the DSL.

Initialize the ISDN BRI terminals.

—End—

Procedure 1

Selecting the card slots

Step

Action

To install ISDN BRI cards, perform the following steps:

1

Identify all the slots that can contain the ISDN BRI cards. First
identify the modules with unused network and peripheral card slots
and then remove the covers from the identified modules. To identify
the modules, use the following Print Programs.

LD 22 to print the system configuration and identify unused
network card slots to install MISPs

LD 20 to list unused IPE card slots to install SILCs, UILCs and
BRSCs

Table 2 "ISDN BRI card location" (page 16)

lists the modules that

can house ISDN BRI cards.

Table 2
ISDN BRI card location

Modules

Supported
Systems

SILCs,
UILCs,
BRSCs

MISPs

NT4N41
Core/Network Module

Large
Systems

Network
slots 0-7

NT8D35
Network Module

81C CPPII

Network
slots 5-12

NT8D37
IPE Module

All systems

IPE slots
0-15

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising