Procedure 21, Procedure 21 "cross-connecting the dsls at the, Figure 25 "uilc port designation label – Nortel Networks NN43001-318 User Manual

Page 70: Figure 25 "uilc port

Advertising
background image

70

Configuring ISDN BRI hardware

power at -48 V (-40 V for Europe), simplexed over the transmit and
receive pairs. The transmit pair is negative with respect to the receive
pair.

Figure 25
UILC port designation label at the cross-connect terminal

Note: The cable pair designated T R is a 2B1Q full-duplex U interface.

Cross-connecting the DSLs

Each SILC provides eight four-wire,

full-duplex ports. These ports connect to building wiring facilities to form
DSLs. Since the DSLs are polarity-sensitive, maintain signal polarity along
each loop as shown in

Figure 26 "Cross-connecting a SILC port to the office

wiring" (page 73)

on

Figure 26 "Cross-connecting a SILC port to the office

wiring" (page 73)

.

Each UILC provides eight two-wire full-duplex ports. These ports connect
to twisted pair building wiring facilities to form DSLs as shown in

Figure 27

"Cross-connecting a UILC port to the office wiring" (page 74)

on

Figure 27

"Cross-connecting a UILC port to the office wiring" (page 74)

. The DSLs

are not polarity-sensitive, and it is not necessary to maintain signal polarity
along each loop.

Procedure 21

Cross-connecting the DSLs at the cross-connect terminal

Step

Action

To cross-connect SILC and/or UILC ports to the building wiring:

1

Identify the card type (SILC or UILC) at the cross-connect terminal.

2

Identify the transmit and receive connections for the SILC and
the TIP and RING connections for the UILC from the label of the
distribution strip.

Refer to

Table 19 "M5317TDX terminal error codes" (page 81)

to

identify ports and their connections for a SILC or UILC.

3

Identify building wires connected at the cross-connect terminal.

4

Cross-connect the pins from the SILC or UILC to the building wiring.

5

Repeat this procedure for each DSL.

—End—

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising