Procedure 29, Performing a call forward no answer test – Nortel Networks NN43001-318 User Manual

Page 91

Advertising
background image

Voice calls

91

Procedure 29

Performing a Call Forward No Answer test

Step

Action

1

Set the FEAT parameter to

FNA

and

SFA

to enable Call Forward No

Answer and Second Level Forward No Answer. (SFA is needed only
to test two levels of Call Forward No Answer.) Use LD 27 to specify
these parameters when configuring the TSP for one of the two voice
ISDN BRI terminal DNs. See "TSP configuration procedures" in
ISDN Basic Rate Interface Feature Fundamentals (NN43001-580).

2

Specify the attendant as the forwarding DN using LD 15. At the
FNAL prompt, enter

ATT

to specify forward to attendant. Refer to

LD 15 in the Software Input Output Administration (NN43001-611)
for more details.

3

From an ISDN BRI terminal, place a call to the ISDN BRI terminal
with the enabled Call Forward No Answer feature and the specified
call forward to attendant.

4

Do not answer the call. After a predetermined number of rings, the
call is forwarded to the attendant. The display on the call-originating
ISDN BRI terminal will not be updated to indicate that the call has
been modified and forwarded to the attendant.

5

Verify the call was forwarded to the attendant by answering the
call at the attendant console. The attendant console will display
the call-originating identification number and the notification of call
redirection.

6

Hang up at the call-originating ISDN BRI terminal to release the
call connection.

—End—

Calling Line Identification Presentation and Restriction

Calling Line Identification Presentation and Restriction allows a calling party
number (Calling Line Identification) to be shown on a called party ISDN BRI
terminal display. Use LD 27 to specify this feature when configuring the TSP
for the ISDN BRI terminal DN. See "TSP configuration procedures" in ISDN
Basic Rate Interface Feature Fundamentals (NN43001-580)
.

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.