Procedure 25, Connecting the system cables to the cross-connect, Terminal – Nortel Networks NN43001-318 User Manual

Page 82: Procedure 25 "connecting the system cables to the

Advertising
background image

82

Configuring ISDN BRI hardware

Error Code

Number

Description

>>32<<

No valid data SPID.

>>90<<

Restricted power mode in use. Lower ringer and speaker
phone volumes apply.

Connecting the ISDN BRI trunks (for trunking applications)

For trunking applications, two procedures are required to connect the ISDN
BRI trunks:

Step

Action

1

Connect the system cables to the cross-connect terminal. See

Procedure 25 "Connecting the system cables to the cross-connect
terminal" (page 82)

.

2

Cross-connect the DSLs at the cross-connect terminal. See

Procedure 26 "Cross-connecting DSLs at the cross-connect
terminal" (page 83)

.

—End—

Procedure 25

Connecting the system cables to the cross-connect terminal

Step

Action

Each card slot equipped with an SILC or UILC requires one NE-A25B
25-pair connector cable. The cables connect to the connectors at the
bottom of the cabinet or at the rear of the MG 1000S. Each connector
is assigned to its corresponding card slot (for example, connector J8 is
assigned to card slot 8).

1

Remove the connector retaining bar from the connector panel
in the lower part of each cabinet or MG 1000S. See

Figure 20

"Cable connectors in main cabinet" (page 68)

and

Figure 21 "Cable

connectors in the expansion cabinet" (page 68)

on

Figure 20 "Cable

connectors in main cabinet" (page 68)

, and

Figure 22 "Cable

connectors in the second expansion cabinet" (page 69)

on

Figure 22

"Cable connectors in the second expansion cabinet" (page 69)

.

2

Connect an NE-A25B cable to each connector associated with
a card slot containing an SILC or UILC circuit card. See

Figure

20 "Cable connectors in main cabinet" (page 68)

and

Figure 21

"Cable connectors in the expansion cabinet" (page 68)

on

Figure 20

"Cable connectors in main cabinet" (page 68)

, and

Figure 22 "Cable

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising