Systems – Nortel Networks NN43001-318 User Manual

Page 55

Advertising
background image

Configuring ISDN BRI trunking with IP expansion cabinets or MG 1000S systems

55

Table 13 "Hardware requirements for ISDN BRI trunking" (page 55)

lists the

hardware required to configure ISDN BRI trunking.

Table 13
Hardware requirements for ISDN BRI trunking

Hardware

Product code

Description

MISP circuit card

NTBK22

The MISP card (NTBK22) is specific to Small
Systems and CS 1000S systems. It performs Data
Link (Layer 2) and Network (Layer 3) processing
associated with the OSI protocol.

SILC circuit card

NT6D70AA
NT6D70BA

-48V North American S/T interface line card
-40V International S/T interface line card

UILC circuit card

NT6D71

U interface line card

A clock controller is required in every cabinet or Media Gateway 1000S
(MG 1000S) equipped with a digital trunk card.

Clock controller

NTAK20AB
NTAK20BB

Stratum 3 clock controller daughterboard
Stratum 4 clock controller daughterboard

Required for conversion from a U to and S/T interface.

Network termination

ISDN network termination unit (NT1), including NT1
standard power supply. Two cables are provided
with the NT1 power supply unit:

178 mm (7 in.) cable for connection between the
power supply and the NT1 unit

captive power cord for connection to an AC
power outlet

Configuring ISDN BRI trunking with IP expansion cabinets or MG
1000S systems

Configure the MISP card slot number for ISDN BRI trunking in LD 27. Refer
to

Table 14 "Correct responses to LOOP and MISP prompts in LD 27" (page

56)

for the correct response to the LOOP prompt.

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising