Figure 16 silc line power options – Nortel Networks NN43001-318 User Manual

Page 62

Advertising
background image

62

Configuring ISDN BRI hardware

Figure 16
SILC line power options

Store unused jumper plugs on position J1 of the SILC for future use.
The following are descriptions of the three options and their jumper
settings.

Normal power on the TX and RX leads. This option is set at
the factory and provides normal power (-48V or -40V) on the
TX lead and battery return (BRTN) on the RX lead to power the
terminal. To implement it, install one jumper plug across the RX
and BRTN pins, and one across the PWR and TX pins, as shown
in

Figure 17 "Jumper plug settings for normal power on the TX

and RX leads" (page 63)

.

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007

Copyright © 2003-2007, Nortel Networks

.

Advertising