Installing ISDN BRI hardware for line applications

21

Procedure 3

Installing the MISP

Step

Action

Once covers have been removed and card slot locations selected for ISDN
BRI cards, install the MISP cards.

1

Hold the MISP by its card-locking devices. Squeeze the tabs to
unlatch the card-locking devices and lift the tabs out and away from
the card.

2

Insert the MISP into the selected card slot of the module so it
engages the card guides in the module.

3

Slide the MISP into the module until it engages the backplane
connector.

4

Push the MISP firmly into the connector using the locking devices as
levers by pushing them toward the card’s front panel.

5

Push the tabs firmly against the front panel of the card so they latch
to the front lip in the module and to the post on the card.

6

Observe the red LED on the MISP faceplate.

If the red LED lights and stays lit continuously without flashing
three times, the card is defective. Remove the MISP, choose a
new MISP, and repeat the installation procedure.

If the red LED lights, flashes three times, and turns off, the
MISP is operating correctly and is configured and enabled. Go
to step 7.

If it lights, flashes three times, and stays lit continuously, the
MISP is operating correctly but is not configured and enabled.
Go to step 7.

7

Repeat steps 1 through 6 for each MISP requiring installation.

—End—

Procedure 4

Removing the MISP

Step

Action

Perform the following steps to remove the MISP.

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318

01.02

Standard

Release 5.0

20 June 2007