C - select vertical barcode, D - select double density block characters – Tally Genicom 6600 User Manual

Page 125

Advertising
background image

Valid Control Sequences

125

(size)

Scale factor affecting both height and unit width of
the bars, ranging from 1-8 (default = 1).

(option)

Human Readable Characters option (default = 1)

1 = No characters

2 = Data Processing font

3 = OCR-A font

4 = OCR-B font

^C - Select Vertical Barcode

Selects Vertical Barcode and sets barcode parameters. Type, height, and size
parameters and options are the same as for Horizontal Barcode. Defaults are
the same as for horizontal (type = 1, height = 80, size = 1).

Command ^C(type);(height);(size)NL

^D - Select Double Density Block Characters

Selects 120 dots per inch and sets Block Character parameters.

Command ^D(height);(width)NL

Argument

(height)

Character Height = 0.12 inches x height multiplier
or

Height Multiplier = Character Height/0.12.

Line feed distance = Unit line x height multiplier,
(Unit line = unit line height set by ^U control
sequence).

(width)

Character width multiplier in the range 2-125
(default = 2). This also affects character cell width.
For example:

Character Width = 0.08 inches x Width multiplier

or

Width Multiplier = Character Width/0.08.

Character Cell Width = 0.10 inches x Width
multiplier

or

Width multiplier = Character cell Width/0.10.