Code ean 13 with hri, Syntax data structure, Example – Tally Genicom 6600 User Manual

Page 244

Advertising
background image

244

Chapter

11

Data Formats of Barcode Types

Code EAN 13 With HRI

Syntax

Data Structure

ASCII DC4 Start code nnnnnnn Separation code nnnnnc Stop code DC4

hex. 14 Start code nnnnnnn Separation code nnnnnc Stop code 14

dec. 20 Start code nnnnnnn Separation code nnnnnc Stop code 20

Example

10 REM code EAN 13 with HRI

20 LPRINT CHR$(27);"[?11~";

30 LPRINT CHR$(26);" K3;111";CHR$(25);

40 LPRINT CHR$(20);":0123456:789012:";CHR$(20);

50 LPRINT CHR$(27);"[?10~"

Figures (n)

Check

Number (c)

Start Code

Separation

Code

Stop Code

ASCII

"0" to "9"

Calculation

see “Check

Number

Calculation”

on page 258.

":"

":"

":"

hex.

30 to 39

3A

3A

3A

dec.

48 to 57

58

58

58