Barcode Header

233

L = EAN 13 without HRI

M = MSI/modified Plessey

N = UPC A with HRI

O = UPC A without HRI

P = UPC E with HRI

Q = UPC E without HRI

R = Delta Distance (IBM)

S = Code 128

T = EAN 128

All commercial barcodes (for labeling systems) of the H, I, K, L, N, O, P, Q
Types can be extended using the barcodes Add-On 2 or Add-On 5

(see “Add-On Barcodes” on page 257).

HRI

HRI = Human Readable Index

HRI characters are centered if enough space is left. If the barcode printout is
smaller than the HRI character field, smaller character density (CPI) is used.
Start and stop codes are not printed as HRI; a space character (SP) will be
stored.

Barcode Width

By specifying an ASCII value from 0 to 3, the barcode width can be defined.
This allows adaption to the scanner specifications, particularly for long-range
scanners.

Table 1

Header

Para-

meter

Normal

Compressed

1

)

older printer

types

(e.g.MT230)

older printer

types

(e.g.MT230)

Width of

the

narrow bar

x = 0
x = 1
x = 2
x = 3

0.53 mm
0.74 mm
1.16 mm
1.38 mm

0.54 mm
0.67 mm
1.09 mm
1.30 mm

0.48 mm
0.69 mm
1.16 mm
1.33 mm

0.32 mm
0.53 mm
0.74 mm
0.95 mm

0.33 mm
0.43 mm
0.65 mm
0.88 mm

0.27 mm

3)

0.37 mm

3)

0.59 mm

3)

0.90 mm

3)

Width of

the

narrow

space

y = 0
y = 1
y = 2
y = 3

0.53 mm
0.74 mm
1.16 mm
1.38 mm

0.54 mm
0.67 mm
1.09 mm
1.30 mm

0.48 mm
0.69 mm
1.16 mm
1.33 mm

0.32 mm
0.53 mm
0.74 mm
0.95 mm

0.33 mm
0.43 mm
0.65 mm
0.88 mm

0.27 mm

3)

0.37 mm

3)

0.59 mm

3)

0.90 mm

3)

Enlarge-

ment

factor

z = 0
z = 1
z = 2
z = 3

2.0 : 1
2.5 : 1
3.0 : 1
3.5 : 1

2.0 : 1

2

)

2.5 : 1

2

)

3.0 : 1

2

)

3.5 : 1

2

)

Advertising