Loc (location of human readable characters), Font, Stop – Tally Genicom 6600 User Manual

Page 209

Advertising
background image

Barcode Command Parameters

209

PDF

Optional parameter that manipulates printing of human readable characters
when it is present. In UPC and EAN barcode this parameter is not necessary
to print human-readable characters (human readable characters are the
default condition for these barcodes).

Enter: PDF

NOTE: Do not use this parameter if a null data field is specified.

LOC (Location of Human Readable Characters)

Optional parameter that changes the location of the human readable
characters.

Enter: No value or B to cause human readable characters to print below the
barcode.

Enter: A to cause human-readable characters to print above the barcode.

FONT

Optional parameter that selects a font for the human readable characters or
suppress printing of human readable characters and trailing portions of the
barcode.

Enter:

N = 10 CPI ASCII

O = 10 CPI OCR-A

X = 10 CPI OCR-B

S = Suppress printing the human readable characters and trailing portions of
the barcode.

Examples:

PDF;A;X

Selects human readable characters above the barcode in 10 CPI
OCR-B.

PDF;S

Suppresses printing of human readable characters in the
barcode.

STOP

This parameter ends the Barcode Command. The printer remains in Create
Mode.

Enter: STOP

This must be present at the end of each individual barcode. For every
BARCODE command you must have a STOP command.

Advertising