Loc (location of human readable characters), Font, Stop – Tally Genicom 6600 User Manual
Page 209
![background image](/manuals/210327/209/background.png)
Barcode Command Parameters
209
Optional parameter that manipulates printing of human readable characters
when it is present. In UPC and EAN barcode this parameter is not necessary
to print human-readable characters (human readable characters are the
default condition for these barcodes).
Enter: PDF
NOTE: Do not use this parameter if a null data field is specified.
LOC (Location of Human Readable Characters)
Optional parameter that changes the location of the human readable
characters.
Enter: No value or B to cause human readable characters to print below the
barcode.
Enter: A to cause human-readable characters to print above the barcode.
FONT
Optional parameter that selects a font for the human readable characters or
suppress printing of human readable characters and trailing portions of the
barcode.
Enter:
N = 10 CPI ASCII
O = 10 CPI OCR-A
X = 10 CPI OCR-B
S = Suppress printing the human readable characters and trailing portions of
the barcode.
Examples:
PDF;A;X
Selects human readable characters above the barcode in 10 CPI
OCR-B.
PDF;S
Suppresses printing of human readable characters in the
barcode.
STOP
This parameter ends the Barcode Command. The printer remains in Create
Mode.
Enter: STOP
This must be present at the end of each individual barcode. For every
BARCODE command you must have a STOP command.