2/5 matrix type a – Tally Genicom 6600 User Manual

Page 226

Advertising
background image

226

Chapter

11

Introduction

This may cause conflict with other emulations, since the above commands
may have different functions in these emulations. For example:

SI

Condensed print

DC4

Reset expanded print

ESC P <n> Proportional spacing ON/OFF

ESC P

Pica

In Barcode Mode, the barcode sequences have priority.

The barcode interpreter can be swited on or off with the MTPL sequences
ESC [? 11 ~ (Barcode ON) and ESC [ ? 10 ~ (Barcode OFF). The typical
transmission procedure should take place as follows:

Barcode Interpreter ON

Transmit mode specification (barcode header, LCP header, secured/
unsecured mode,...)

Transmit barcode / LCP

Barcode OFF

NOTE: The mode specifications are saved temporarily and must only be sent

to the printer once. The specification remains valid until the printer is
switched off.

Note the following explanatory information:

Every sequence description begins with a header in which the function and
short form of the sequence of the barcode Types are listed, e.g.:

The header is followed by the data structure in ASCII, hexadecimal and
decimal representation with the necessary parameters, e.g.:

ASCII

DC4

start code

n ... n

stop code

DC4

hex.

14

start code

n ... n

stop code

14

dec.

20

start code

n ... n

stop code

20

The syntax for the parameters, the start, separate and stop code is
represented as follows:

Table 42. Syntax Parameters

Figures (n)

Start Code

Stop Code

ASCII

0 to 9

;

;

hex.

30 to 39

3A

3A

dec.

48 to 57

58

58

2/5 Matrix

Type A

Advertising