This may cause conflict with other emulations, since the above commands
may have different functions in these emulations. For example:
SI
Condensed print
DC4
Reset expanded print
ESC P <n> Proportional spacing ON/OFF
ESC P
Pica
In Barcode Mode, the barcode sequences have priority.
The barcode interpreter can be swited on or off with the MTPL sequences
ESC [? 11 ~ (Barcode ON) and ESC [ ? 10 ~ (Barcode OFF). The typical
transmission procedure should take place as follows:
•
Barcode Interpreter ON
•
Transmit mode specification (barcode header, LCP header, secured/
unsecured mode,...)
•
Transmit barcode / LCP
•
Barcode OFF
NOTE: The mode specifications are saved temporarily and must only be sent
to the printer once. The specification remains valid until the printer is
switched off.
Note the following explanatory information:
Every sequence description begins with a header in which the function and
short form of the sequence of the barcode Types are listed, e.g.:
The header is followed by the data structure in ASCII, hexadecimal and
decimal representation with the necessary parameters, e.g.:
ASCII
DC4
start code
n ... n
stop code
DC4
hex.
14
start code
n ... n
stop code
14
dec.
20
start code
n ... n
stop code
20
The syntax for the parameters, the start, separate and stop code is
represented as follows:
Table 42. Syntax Parameters
Figures (n)
Start Code
Stop Code
ASCII
0 to 9
;
;
hex.
30 to 39
3A
3A
dec.
48 to 57
58
58
2/5 Matrix