APPENDIX A

Message

Comments

MFD1 CONFIG – MFD1 configuration
error. Config service req’d.

The MFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.

SW MISMATCH – GDU software
version mismatch. Xtalk is off.

The MFD and PFD have different software versions installed. The G1000 system
should be serviced.

PFD1 COOLING – PFD1 has poor
cooling. Reducing power usage.

The PFD and/or MFD is overheating and is reducing power consumption by dimming
the display. If problem persists, the G1000 system should be serviced.

PFD2 COOLING – PFD2 has poor
cooling. Reducing power usage.
MFD1 COOLING – MFD1 has poor
cooling. Reducing power usage.
PFD1 KEYSTK – PFD1 [key name] Key
is stuck.

A key is stuck on the PFD and/or MFD bezel. Attempt to free the stuck key by
pressing it several times. The G1000 system should be serviced if the problem
persists.

PFD2 KEYSTK – PFD2 [key name] Key
is stuck
MFD1 KEYSTK – MFD1 [key name] Key
is stuck.
CNFG MODULE – PFD1 configuration
module is inoperative.

The PFD1 configuration module backup memory has failed. The G1000 system
should be serviced.

PFD1 VOLTAGE – PFD1 has low
voltage. Reducing power usage.

The PFD1 voltage is low. The G1000 system should be serviced.

PFD2 VOLTAGE – PFD2 has low
voltage. Reducing power usage.

The PFD2 voltage is low. The G1000 system should be serviced.

MFD1 VOLTAGE – MFD1 has low
voltage. Reducing power usage.

The MFD voltage is low. The G1000 system should be serviced.

DATABASE MESSAGE ADVISORIES

Message

Comments

MFD1 DB ERR – MFD1 aviation
database error exists.

The MFD and/or PFD detected a failure in the aviation database. Attempt to reload
the aviation database. If problem persists, the G1000 system should be serviced.

PFD1 DB ERR – PFD1 aviation
database error exists.
PFD2 DB ERR – PFD2 aviation
database error exists.
MFD1 DB ERR – MFD1 basemap
database error exists.

The MFD and/or PFD detected a failure in the basemap database. The G1000 system
should be serviced.

PFD1 DB ERR – PFD1 basemap
database error exists.
PFD2 DB ERR – PFD2 basemap
database error exists.

Advertising