532

APPENDIX A

GIA 63W MESSAGE ADVISORIES

Message

Comments

GIA1 CONFIG – GIA1 config error.
Config service req’d.

The GIA1 and/or GIA2 configuration settings do not match backup configuration
memory. The G1000 system should be serviced.

GIA2 CONFIG – GIA2 config error.
Config service req’d.
GIA1 CONFIG – GIA1 audio config
error. Config service req’d.

The GIA1 and/or GIA2 have an error in the audio configuration. The G1000 system
should be serviced.

GIA2 CONFIG – GIA2 audio config
error. Config service req’d.
GIA1 COOLING – GIA1 temperature
too low.

The GIA1 and/or GIA2 temperature is too low to operate correctly. Allow units to
warm up to operating temperature.

GIA2 COOLING – GIA2 temperature
too low.
GIA1 COOLING – GIA1 over
temperature.

The GIA1 and/or GIA2 temperature is too high. If problem persists, the G1000 system
should be serviced.

GIA2 COOLING – GIA2 over
temperature.
GIA1 SERVICE – GIA1 needs service.
Return the unit for repair.

The GIA1 and/or GIA2 self-test has detected a problem in the unit. The G1000 system
should be serviced.

GIA2 SERVICE – GIA2 needs service.
Return the unit for repair.
HW MISMATCH – GIA hardware
mismatch. GIA1 communication
halted.

A GIA mismatch has been detected, where only one is WAAS capable. The G1000
system should be serviced.

HW MISMATCH – GIA hardware
mismatch. GIA2 communication
halted.
MANIFEST – GIA1 software
mismatch, communication halted.

The GIA1 and/or GIA 2 has incorrect software installed. The G1000 system should be
serviced.

MANIFEST – GIA2 software
mismatch, communication halted.
MANIFEST – GFC software mismatch,
communication halted.

Incorrect servo software is installed, or gain settings are incorrect.

COM1 TEMP – COM1 over temp.
Reducing transmitter power.

The system has detected an over temperature condition in COM1 and/or COM2. The
transmitter operates at reduced power. If the problem persists, the G1000 system
should be serviced.

COM2 TEMP – COM2 over temp.
Reducing transmitter power.
COM1 SERVICE – COM1 needs
service. Return unit for repair.

The system has detected a failure in COM1 and/or COM2. COM1 and/or COM2 may
still be usable. The G1000 system should be serviced when possible.

COM2 SERVICE – COM2 needs
service. Return unit for repair.